Skip to content
Start » Blog » Troubleshoot

XenServer – Activate iSCSI Multipathing afterwards

Beitragsbild

On a new XenServer 7.1 environment I had the issue that the afterwards created 2nd Storage Network for iSCSI Multipathing was not used by XenServer.
– Ping on the second storage network to the storage device was fine
– /etc/multipathing.conf is configured
– Multipathing was aktivated
– When scanning the LUN the second network export was shown.

This post on the citrix community brough me to the right direction:

In short:
iscsiadm -m node
# Shows current targets

iscsiadm -m session
# Shows current sessions, note that the output differs from the first command

iscsiadm -m node –login
# Take any IQN where multipathing is not established let the xenserver perform the iscsi login

Voila! In my case it directly refreshed all LUNs and multipathing is effective for all SRs

MS
Mauricio Schäpers
VS Qloud Solution

Schreibt im VSQloud-Blog von Technikern für Techniker über Citrix, Endpoint Management und den Betrieb hochverfügbarer Cloud-Infrastrukturen.

An den Anfang scrollen
Translate »
No results found...